Hearing in Dentists Compared with Other Academics
Hearing assessment in dental practitioners and other academic professionals from an urban setting.
Published research · 2014
Peer-reviewed study published in Head & Face Medicine.
Willershausen B., Callaway A., Wolf T. G., Ehlers V., Scholz L., Wolf D., Letzel S. · Published 18 January 2014
What the study set out to do
Dentists work every day with high-speed handpieces and other noisy equipment, which could put their hearing at risk. The researchers compared the hearing of dentists with that of other academic professionals to see whether there was a difference.
How it was done
115 participants were enrolled, and after exclusions the data from 53 dentists and 55 other academic professionals were analysed. Their average age was about 52 years. Hearing was tested in both ears from 125 Hz to 8 kHz with an Oscilla USB audiometer. Participants with a cold, blocked ears or abnormal hearing thresholds were excluded. A questionnaire gave information on health history and years in the profession.
What was found
Air-conduction hearing in the dentists tended to be slightly poorer than in the control group. The difference was statistically significant at 3 and 4 kHz in both ears. No significant differences were found for bone conduction.
Why it matters
According to the authors, hearing impairment was slightly more common among dentists. Since other noise exposure was similar in both groups, they suggest that working with high-speed handpieces and other noisy devices may be an extra burden on hearing.
Reference
Willershausen, B., Callaway, A., Wolf, T. G., Ehlers, V., Scholz, L., Wolf, D., & Letzel, S. (2014). Hearing assessment in dental practitioners and other academic professionals from an urban setting. Head & Face Medicine, 10, 1. Published 18 January 2014. https://doi.org/10.1186/1746-160X-10-1
Keywords: hearing assessment, dental practitioners, audiometric determination, urban setting, occupational noise, Oscilla, USB audiometer